INTERBALL
Magnetometer FGM-1
The main technical parameters
Flux gate magnetometer
Sensor noise level : 0,005nT/sqrt Hz at 1 Hz
---------------------------Frequency range: -- Dynamic range: -- Resolution
Analogue telemetry (RTK) . . . . . . . . . . . 0 - 25 Hz . . . . . . . ±128 nT . . . . . . . . 1,0 nT
Digital telemetry (OPERA,SSNI) . . . . . . 0 - 6 Hz . . . . . . . ±256 nT . . . . . . . . 2,0 nT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±32 nT . . . . . . . 0,25 nT
Current probe
Split probe sensor FM-2 :
Sensor surface : 2 x 50 cm²
Sensitivity :
- on the output of the FGM-I experiment : 10,66 mV/nA
- on the MIF-M output : 2,13 mV/pA 20 * 10-15 A/cm²/sqrt Hz
Frequency range : 0 - 0.01 Hz -20 dB
. . . . . . . . . . . . . . 0,01 - 20.000 Hz -3 dB
Mass budget:
- DM-1 : 181 g
- BE-DM-1 : 323 g
- Thermal cover DM-1 : 26 g
- Thermal cover BE-DM-1 : 46 g
- Split probe sensor BD-7a : XX g
Overall mass : 576 g
Power consumption ±27 volts :
- nominal : 42 mA
- maximal : 60 mA
Dimensions :
- DM-1 : 189 x 46 x 40 mm
- BE-DM-1 : 150 x 60 x 42 mm
- BD-7a : Ø45 mm, length : XXX mm
|